Articles
Spark tension with positive polarity atmospheric impulses for short insulation distances, using electrodes tip to tip and tip-plate
Published 2003-12-03
Keywords
- Spark voltage,
- atmospheric impulse,
- up - and - down,
- maximum likelihood,
- correction for atmospheric conditions
How to Cite
Chacón Velasco, J. C., & Castellanos Z., H. D. (2003). Spark tension with positive polarity atmospheric impulses for short insulation distances, using electrodes tip to tip and tip-plate. Revista UIS Ingenierías, 2(2), 87–93. Retrieved from https://revistas.uis.edu.co/index.php/revistauisingenierias/article/view/2311
Abstract
We present the results of a study to determine analytical expressions that relate the spark voltage (V50%) of the insulation under the air to the inter electronic separation distance (up to 85 cm). Using standard atmospheric pulses. These expressions may be used in the Colombian electrical system to the atmospheric conditions of the location of the equipment and applicable to short distances. The "Up and down" methodology was used to determine the VJO% and the maximum likelihood method for its statistical treatment. The study was carried out using the tip-tip and tip-standard configurations.
Downloads
Download data is not yet available.
References
ALLIBONE, T. E. Y DRINGD. Influence of hwnidíty on lhe breakdown of sphere and rodgaps under impulse voltages of short and long wave fronts. Proc. IEE. Vol119, N"9. September 1972. p.p.1417-1422.
BROWN, G., Melhod of tuaxinuun like lihood applied to the analysis of flashover data. IEEE Transactions on power apparatus and systerns. Vol. Pas-88. N°12. December 1969. p.p.1823-1830.
CHACÓN, J. C., Contrastación de las normas existentes en el cálculo de los factores de corrección por condíciones atmosféricas utilizando electrodos punta-punta. Bucararnanga, 1995, 141p. Tesis de grado (Maestria en Potencia Eléctrica). Universidad Industrial de Santander. Escuela de Ingeniería Eléctrica
LASTRE, H. H., Contrastación de las normas existentes en el cálculo de los factores de corrección por condíciones atmosféricas utilizando electrodospunta-placa. Bucaramanga, 1995, 150p. Tesis de grado (Maestria en Potencia Eléctrica). Universidad Industrial de Santander. Escuela de Ingeniería Eléctrica.
DAVIES, A. J. Effect of hwnidity and gasdensity on switching impulse breakdown of short airgaps. IEE Proceedings. Vol. 135. PI. A, N"l. January 1988. p.p.59-68
DAVIES, A. J. Statistical analysis of flashover data using a generalized like lihoodmethod. lEE Proceedings. Vol. 135. Pt. A. N"l. January 1988. p.p.79-87.
IEEE Standard Techniques for High-Voltage Testing. Publication Std4-1995. p.p.92-98.
WALPOLE, R.y MYERS, R. Prohabilidad y estadística. México: Y edición. Mc GrawHill. 1995.
RUGELES, J. Conceptos básicos en Técnicas de la alta tensión. Bucaramanga: 2a edición. Publicaciones UIS. 1991.
lEC. Technical cornmitte No42. High Voltage testtecltniques. 1988.
HAUSCHlL D. W., MOSCH. W., Statistical Techniques for High-voltage engineering. London: la edición. Peter Peregrinus. 1992.
BROWN, G., Melhod of tuaxinuun like lihood applied to the analysis of flashover data. IEEE Transactions on power apparatus and systerns. Vol. Pas-88. N°12. December 1969. p.p.1823-1830.
CHACÓN, J. C., Contrastación de las normas existentes en el cálculo de los factores de corrección por condíciones atmosféricas utilizando electrodos punta-punta. Bucararnanga, 1995, 141p. Tesis de grado (Maestria en Potencia Eléctrica). Universidad Industrial de Santander. Escuela de Ingeniería Eléctrica
LASTRE, H. H., Contrastación de las normas existentes en el cálculo de los factores de corrección por condíciones atmosféricas utilizando electrodospunta-placa. Bucaramanga, 1995, 150p. Tesis de grado (Maestria en Potencia Eléctrica). Universidad Industrial de Santander. Escuela de Ingeniería Eléctrica.
DAVIES, A. J. Effect of hwnidity and gasdensity on switching impulse breakdown of short airgaps. IEE Proceedings. Vol. 135. PI. A, N"l. January 1988. p.p.59-68
DAVIES, A. J. Statistical analysis of flashover data using a generalized like lihoodmethod. lEE Proceedings. Vol. 135. Pt. A. N"l. January 1988. p.p.79-87.
IEEE Standard Techniques for High-Voltage Testing. Publication Std4-1995. p.p.92-98.
WALPOLE, R.y MYERS, R. Prohabilidad y estadística. México: Y edición. Mc GrawHill. 1995.
RUGELES, J. Conceptos básicos en Técnicas de la alta tensión. Bucaramanga: 2a edición. Publicaciones UIS. 1991.
lEC. Technical cornmitte No42. High Voltage testtecltniques. 1988.
HAUSCHlL D. W., MOSCH. W., Statistical Techniques for High-voltage engineering. London: la edición. Peter Peregrinus. 1992.